Lucene search

K
SiemensSimatic S7-1500 Cpu Firmware

7 matches found

CVE
CVE
added 2022/04/12 9:15 a.m.141 views

CVE-2022-25622

The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by send...

7.5CVSS6.2AI score0.00117EPSS
CVE
CVE
added 2019/10/10 2:15 p.m.110 views

CVE-2019-10936

Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition.

7.5CVSS7.5AI score0.01992EPSS
CVE
CVE
added 2014/08/17 11:55 p.m.58 views

CVE-2014-5074

Siemens SIMATIC S7-1500 CPU devices with firmware before 1.6 allow remote attackers to cause a denial of service (device restart and STOP transition) via crafted TCP packets.

7.1CVSS6.8AI score0.13713EPSS
CVE
CVE
added 2014/03/16 2:6 p.m.43 views

CVE-2014-2257

Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted ISO-TSAP packets.

7.8CVSS6.7AI score0.00902EPSS
CVE
CVE
added 2014/03/16 2:6 p.m.41 views

CVE-2014-2259

Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTPS packets.

7.8CVSS6.7AI score0.01597EPSS
CVE
CVE
added 2014/03/16 2:6 p.m.40 views

CVE-2014-2255

Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTP packets.

7.8CVSS6.7AI score0.01597EPSS
CVE
CVE
added 2016/02/08 4:59 p.m.38 views

CVE-2016-2200

Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to cause a denial of service (STOP mode transition) via crafted packets on TCP port 102.

7.8CVSS7.4AI score0.09239EPSS